Approved Document Bushfire Hazard and Mitigation Plan 25 02 2025 MCU21/0110 - Negotiated

of 39
                                                                                                                                                      23



         Performance outcomes                                Acceptable outcomes                                             Response
PO6                                                AO6.1                                                R6.1
Roads provide for easy and safe evacuation         The road layout provides for through-roads           Not applicable
of residents of premises and access by             and avoids cul-de-sacs and dead-end roads.
emergency services.
                                                   OR
                                                                                                        R6.2
                                                   AO6.2
                                                                                                        Not applicable
                                                   The development has a perimeter road
                                                   reserve with a minimum width of 20 metres
                                                   and maximum gradient of 12.5%.
                                                   OR
                                                   AO6.3                                                R6.3
                                                   Cul-de-sacs or no-through roads are provided Resort Drive is a no-through road with a road
                                                   with fire trails or access easements, which are reserve width of 12m, which is capable of being
                                                   capable of being navigated by conventional      navigated by conventional vehicles and which
                                                   vehicles and which link to through roads.       links to Links Drive.
                                                   AO6.4                                                R6.4
                                                   Safe access and egress is available at all    Safe access and egress is available at all times
                                                   times to all of the development for emergency to all of the development for emergency
                                                   vehicles and personnel.                       vehicles and personnel.
                                                   AO6.5                                                R6.5
                                                   Where an emergency access point is required, No further emergency access is required
                                                   it complies with the relevant works codes and
                                                   PSP6 Engineering Design Standards.

Lot design
PO7                                                AO7                                                  R7.1


                                  RF17-040 – Boutique Hotel – Noosa Springs – Bushfire Hazard Assessment & Management Plan
Rob Friend & Associates Pty Ltd                                                                                                     25th of February 2025

Log in to download the original (Approved Document Bushfire Hazard and Mitigation Plan 25 02 2025 MCU21_0110 - Negotiated.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.