Attachment 6 - Stormwater Management Plan
The original of this document is very large (26.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnR2015: NOOSA LANDFILL - STORMWATER MANAGEMENT PLAN Figure 9 – Proposed HES Basin Outlet and Flood Levels With a Q10 flood level of RL 12.50, the emergency spillway would be required to be as a minimum RL 12.50. To achieve fall in the outlet channel to the low levels on the northern boundary, the piped outlet would be required to be above approximately RL 12.1. The outlet pipe could be set at a minimum of RL 12.1 to minimise fill required on the pad. A frog flap would be required to be installed on the outlet to limit backflows during flood events, however, the basin would still be operational during these events with outflows able to occur over the spillway (above the flood event) with settling occurring in the basin. If this does not occur another 0.5m of fill will be required across the entire pad. Based on a basin settling depth of 1.2m and piped outflow of RL 12.1, the emergency spillway would be approximately 13.3, with an inflow at approximately RL 13.9 to allow for fall through the basin and inlet channel. Pad levels would be required to be above RL 14.0 to ensure fall to the basin. Where drains are used instead of bunds to direct flow to the basin (recommended to avoid ponding on pads), additional fill would be required to achieve fall and freeboard within drainage channels. Details on the SW2 HES basin sizing are provided in Appendix D. 4.2.1. MANAGEMENT OF NUTRIENTS FROM GREEN WASTE AREA The current arrangement on site is to utilise a bio-retention basin to treat runoff from the Green Waste Area. To avoid construction of a bio-retention basin and a HES basin, the use of a floating wetland could be trialled in the end of the HES basin. Sunshine Coast Council are currently trialling this at their facilities and should be contacted prior to proceeding to design. Figure 10 – Floating Wetland installed at SCC landfill 4.2.2. DETAILED DESIGN Detailed design of the proposed HES basin and drainage will be required in consultation with NSC once pad layout and levels have been determined. This options provided for the SW2 augmentation in this report are concept only to provide guidance around potential options. Environment. Engineering. Education. PAGE 12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.