19660 OPW26-0033 - response to info request
Response
As per our discussions and emails with Daniel Epps, we consider that the stormwater design
provided does comply with conditions 37 & 38 of the higher order approval. In addition, we have
checked Council's PSP for Stormwater design standards that apply and it refers to QUDM
(extract below - item 1 (a) (i)). QUDM requires urban drainage in low density areas to be
designed to convey Q2 (AEP 39%) - extract attached (table 7.3.1).
PLANNING SCHEME EXTRACT
QUDM EXTRACT
As such, the HGL shown on our long section drawings for a Q2 event is the correct design
event and confirms that the pits downstream of pit 6/A will not surcharge. We have removed
reference to surcharge pits on the long section which was a drafting error.
Page 5 of 9
Tod Job Number: 19660-OPW2-A
See the original