Decision Notice plus copy sent to Referral Agencies [As Published] · 132007.2398
2007/2398
74. The sewer connection shall be generally in accordance with the Sewerage Layout Plan
Drawing No N07058-DA10 Issue E dated 22/01/09 and the Proposed Sewer Details N07058-
DA20 Issue (A) dated 22/01/2009 by Brown Consulting. A Development Permit for
Operational Works is required.
75. A new sewer connection must be provided within the property boundary of Lot 4 RP 215922.
76. The applicant must provide written approval from all property owners through which external
sewers will traverse, to enter, construct and provide a sewer easement. This must be submitted
prior to the associated development application for Operational Works.
Water Supply
77. The site must be connected to Council's existing town water supply and be constructed in
accordance with Council's standards and requirements at no cost to Council.
78. Works be carried out in accordance with the approved findings of the water supply network
analysis by Worley Parsons and dated 10 June 2008
79. The existing 100mm diameter watermain within Pearson Road must be upgraded between the
existing 150mm diameter main in Carruthers Court to the existing 150mm diameter main to the
North in Pearsons Road
80. The water connection to the water reticulation system shall extend to the property boundary and
be metered. All fees for the supply of water meters shall be paid to the Council
81. For Multiple Uses (including Building Format Plans, Group Title Plans, etc) the development shall
be served by:
81.1 Single Body Corporate water meter to measure the total water consumption (including fire
hose reels, but excluding fire hydrants and fire sprinkler systems)
81.2 Individual water meters to each tenement capable of being separately rated. These
meters must be supplied and installed in accordance with Councils requirements
81.3 All water meters must be located in an easily assessable location to facilitate
unhindered reading by Council and/or Council’s contracted water meter readers, and
not behind fences or locked gates
81.4 A fire service (fully testable single detector check with metered bypass), where applicable,
for flows to fire hydrants and fire sprinkler systems (excluding fire hose reels)
82. Fire hydrants are to be provided throughout the development in accordance with Council
Engineering Design Standards and in accordance with Queensland Fire Service Standards.
Service Easements
83. A registered easement shall be created over the zone of influence of the proposed sewer
mains within the subject site and on the adjoining property Lot 4 RP 215622. The easements
shall generally be parallel to and centred over the sewer main and be equivalent in width to
twice the depth to invert level of the sewer at the deepest point (measured from the finished
surface) and be no less than 3.0m wide overall. In this regard a licensed surveyor shall
accurately locate all sewer mains and determine the necessary width of the easement, which
shall be shown on any plans submitted for Operational Works / Building Works approval. To
this extent the surveyor shall certify that the sewer and the zone of influence is wholly
contained within the easement to be created. The applicant must be pay all costs associated
with the acquisition and the registration of easement/s.
84. The Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking in writing that
the Title Deed and the easement documents will be lodged at the Land Titles Office and any
additional Titles Office forms or requisitions requiring the consent of Council will be attended to
promptly.
Page 10 of 32
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice plus copy sent to Referral Agencies [As Published]Related documentApplication case desk ↗
About this file
- File size
- 644 KB (small file)
- File type
No other editions are linked here.