03.1 - Decision Notice s63

Attached to the e-mail Operational Works Application OPW21/0120 - DA Form 1, Plans, Civil Plans, Surveyor Plan, Certifier DA.

of 8

Page text shows just the words. Original shows the document exactly as it was published.

                                                   ATTACHMENT A
                                              BUILDING CONDITIONS
      (2)
                 2. For the purposed of (1)(d)-(f) the following nominal credits apply:
                 a) 0.5 star where a building includes an outdoor living area, the roof covering of which achieves a Total R
      Value of at least 1.5 downward heat flow;
                 b) 1 star where a building includes an outdoor living area the roof covering of which achieves a Total R
      Value of at least 1.5 for downward heat flow and the outdoor living area includes a permanently installed ceiling
      fan with a speed controller and a blade rota on diameter of not less than 900mm;
                 c) 1 star where a building has a solar photovoltaic system of at least 1kW in capacity (maximum power
      output) installed.
      A2. 1. The thermal performance of sole occupancy units in class 2 buildings complies with JV1 of the BCA 2009
      (Volume 1) except that:
                 a) for JV1(a)(i) each sole occupancy unit has a so ware ra ng of not less than 4 stars and;
                 b) for JV1(a)(ii) the average so ware ra ng of all sole occupancy units is not less than 5 star; and
                 c) the deemed to sa sfy provisions of Sec on J of the BCA 2009 (Volume 1) have no effect for sole
      occupancy units
                 2. For the purposes of calcula ng the average so ware ra ng under A2(1)(b) of all sole occupancy units
      of a class 2 building in climate zones 1 or 2 the following credits apply towards the so ware ra ng for each sole
      occupancy unit;
                 a) 0.5 star where a sole occupancy unit includes an outdoor living area, the roof covering of which
      achieves a Total R Value of 1.5 for downward heat flow; or
                 b) 1 star where a sole occupancy unit includes an outdoor living area that has at least one permanently
      fixed ceiling fan with a speed controller and a blade rota on diameter of not less than 900mm and the roof
      covering achieves a Total R Value of 1.5 for downward heat flow
                 3. To achieve a credit under A2 (2)(b) an air-condi oner that services any room directly adjacent to an
      outdoor living area must automa cally shut down when an external door that provides access to the outdoor living
      area is open for more than 1 minute.
      A3. Class 1 buildings, including a verandah, balcony or an enclosed class 10a building a ached to a class 1 building,
      have:
                 a) ar ficial ligh ng that complies with Part 3.12.5.5 of BCA 2010 (Volume 2); or
                 b) Energy efficient ligh ng for a minimum of 80 percent of total fixed ar ficial ligh ng.
      A4. Sole occupancy units of class 2 buildings, including a verandah, balcony or an enclosed class 10a building
      a ached to a class 2 building, have energy efficient ligh ng for a minimum of 80 percent of total fixed ar ficial
      ligh ng
      A5. A water heater in a hot water supply system can be an electrical resistance heater or any other type of heater.
      A6. In class 1 and class 2 buildings, in areas serviced by water service provider, all shower rosees have a minimum 3
      star Water Efficiency Labelling and Standards ra ng
      A7. In class 1 and class 2 buildings, in areas serviced by a water service provider, all toilets cisterns;
                 a) have a dual flush func on and have a minimum 4 star Water Efficiency Labelling and Standards ra ng;
      and
                 b) are compa ble with the size of the toilet bowl to allow for proper func oning of the toilet
      A8.In class 1 and class 2 buildings, in areas serviced by a water service provider, tap ware with a minimum 3 star
      Water Efficiency Labelling and Standards ra ng serves:
                 a) laundry tubs; and
                 b) kitchen sinks; and
                 c) basins
      A9. Each meterable premises has an electricity sub-meter installed which measures only the electricity supplied to
      that meterable premises.
      A10. The electricity sub-meter is:
                 a) installed in a common area; and
                 b) free of hindrance or obstruc on to a person authorised to rear and/or maintain the electricity sub-
      meter
      A11. A meter label iden fying which meterable premises it is associated with is affixed or located adjacent to the
      electricity sub-meter for each meterable premises.
9     Any retaining walls greater than 1.0m in height and not included on the approved plans, will require a separate
      Building Permit.
10    All roofwater is to be discharged in accordance with the condi on as shown on the approved plans and in any case
Attachment A                                          Ref: 00011210                                              Page 4 of 8
Log in to download the original file

03.1 - Decision Notice s63.pdf · 288 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.