19 Viewland Drive Final Renovation Plans Stage 16 · OPW19/0180
Attached to the e-mail Operational Works Application OPW19/0180 - DA Form 1 - Supporting information document - Plans - Plans - Arborist Report - at 19 Viewland Drive Noosa Heads.
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES 19 viewland drive, noosa heads 4567 lot 8 on RP88535 TIMBER FRAMING AND CONSTRUCTION 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN DOMESTIC BUILDING CODE. 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL. 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM JOINT GROUP J2. 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH AS 1684.2 2010 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES solar tube 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO fw SETOUT AND ORDERING OF MATERIALS 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER solar tube AS NO RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED 900 1500 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR HER OWN WORK 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000 solar tube DOMESTIC SMOKE ALARMS 1200 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED refs WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT LEGEND TOTALS REGULATION 2016 solar tube 1 SINGLE GPO 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE W WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL DN 1W SINGLE WEATHER PROOF GPO AND INTERCOM SYSTEMS. 2 2 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD DOUBLE GPO WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE 2 DOUBLE WEATHER PROOFGPO REMOVED FROM DEVICE 2W 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS TO EXISTING RESIDENCES 1200 LED BLADE LIGHTS S INDICATES THE LOCATION OF WIRED SMOKE ALARMS LED DOWNLIGHT DN GLAZING SWITCH 1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND TWO WAY SWITCH SUBJECT TO CONFIRMATION UPON SITE MEASURE TV 2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT FOXTEL TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR upper floor electrical layout PHONE PRIVACY OPTIONS DATA ELECTRICAL AND ENERGY EFFICIENCY SMOKE DETECTORS 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED CHANDELIERS INDICATIVE ONLY PENDANT LIGHTS DOWNPIPES ELECTRICAL TEMPLATE FOR USE BY OWNER/BUILDER TWIN FLOOD LIGHTS ALL LOCATED DOWNPIPES INDICATIVE ONLY AND CONFIRMED AT TIME OF ROOFING CONSTRUCTION CENSOR AND COMPLIANCE EXTERNAL WALL LIGHTS CEILING FANS EXHAUST FAN LIGHT FAN LIGHT HEATER NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROPOSED: CLIENT: RON O'GRADY BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 14 of 16 DATE: ISSUE NO: RENOVATION EXTENSION PH: 0417 602 074 TBC PH: 0403 481 474 SCALE: 1:100 14 AUG 2019 P -FINAL NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
19 Viewland Drive Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.