Council archive · source document
19 Viewland Drive Final Renovation Plans Stage 16 · OPW19/0180
Attached to the e-mail Operational Works Application OPW19/0180 - DA Form 1 - Supporting information document - Plans - Plans - Arborist Report - at 19 Viewland Drive Noosa Heads.
Plans and drawings: the text below has words only, no drawings.
SITE DETAILS 19 viewland drive, noosa heads 4567 lot 8 on RP88535 RESPONSIBILITY CANNOT BE TAKEN FOR SITE LEVELS THEREFORE THE BUILDER SHOULD VERIFY THESE LEVELS BEFORE COMMENCING ANY WORK CUT AND FILL, LEVELS SHOWN ON THIS PLAN ARE APPROXIMATE INTERPRETATION, AND MAY VARY TO FINISHED LEVELS ON SITE AT COMMENCEMENT AND COMPLETION OF WORKS PLATFORM IMMEDIATELY SURROUNDING RESIDENCE TO FALL AWAY FROM RESIDENCE AT A SLOPE OF 1 IN 15MIN. DRIVEWAY SLOPE NOT TO EXCEED A MAX 1 VERTICAL TO 4 HORIZONTAL APPROX. 20.117 20.117 90d00'00" 90d00'00" 1000MAX HIGH TIMBER RETAINING WALLS TO HAVE 65mm DIA. AG. PIPE (DISCHARGE TO STORMWATER) + GRADED GRANULAR BACK FILL BEHIND AND TO BE CONTAINED WITHIN SITE 5400 approximate location of rear retaining wall 6000 and excavation intended for drying court RETAININING WALLS EXCEEDING THIS ARE TO BE ENGINEERED ALSO (to be confirmed on site) proposed extension DISPOSE SEWERAGE IN ACCORDANCE WITH LOCAL AUTHORITY 9675 10275 PREPARED DRAINAGE PLAN dp dp DISCHARGE ALL STORMWATER TO COUNCIL S/WATER SYSTEM solar tube (DOWNPIPE DESIGN, SIZE AND LOCATION BY BUILDER AND ROOFING REQUIREMENTS, AND MAYBE ADJUSTED TO SUIT SITE CONDITIONS. proposed deck DOWNPIPES: extension 2705 90DIA OR 100x50 DOWNPIPES TO STORMWATER PIPES 100mm MIN COVER 1 IN 100MIN FALL 2100 dp DN TERMITE PROTECTION 0d00'00" DN 30.175 180d00'00" BUILDER TO PROVIDE TERMITE CONTROL SYSTEM IN ACCORDANCE 0d00'00" 30.175 180d00'00" WITH AS.3660.1 30.175 30.175 dp TERMITE PROTECTION GENERALLY SHALL BE BY GROUND FLOOR SLAB 3217 AS BARRIER AND EXPOSED EDGE OF SLAB AS VISUAL BARRIER solar tube solar tube solar tube TERMI MESH OR SIMILAR COLLARS TO SLAB PENETRATIONS TERMITE RESISTENT (HAZARD LEVEL H2) TIMBER FRAMING GENERALLY 3817 BUILDER TO PROVIDE ACCESS FOR CLEAR VISUAL INSPECTIONS TO THE existing existing residence ENTIRE PERIMETER OF THE HOUSE, AND THE EXPOSED EDGE OF CONCRETE SLABS 3817 residence 2700 ENERGY EFFICIENCY ALL TOILETS TO BE INSTALLED WITH 3/4.5 DUAL FLUSH CISTERNS OR BETTER dp ALL SHOWER HEADS TO HAVE CERTIFIED AAA WATER CONSERVATION RATING DN ALL TAPS TO HAVE CERTIFIED AAA WATER CONSERVATION RATING dp ENERGY EFFICIENT LIGHTING TO BE USED FOR MIN OF 80% OF FLOOR AREA HOT WATER SYSTEM TO BE GAS BOOSTED SOLAR HOT WATER SYSTEM proposed (OR OTHER APPROVED) OF SIZE TO SUIT REQUIREMENTS. proposed trellis 7100 6010 driveway extended to entry extension 6100 GENERAL 4570 suit new garage entry direction of electric gate ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH: 20.117 THE BUILDING CODE OF AUSTRALIA 20.117 27d00'00" THE BUILDING ACT 1975 27d00'00" 5000 STANDARD BUILDING REGULATION 1993 approx location of boulder retaining BUILDING REGULATION 2006 (stairs and landscaping to be determined QDC QUEENSLAND DEVELOPMENT CODE on site by owner/builder) AS 1684-2006 TIMBER FRAMING CODE 500x1800h block piers + electric gate behind ALL TIMBER FRAMED WALLS TO WET AREAS TO BE LINED WITH FC 1500h steel frame fence each side WC'S TO BE A MIN CLEAR FINISHED WIDTH OF 900mm DOORS TO WC'S TO HAVE LIFT OFF HINGES SMOKE ALARMS TO BE PROVIDED AS PER BCA & AS3786 VIEWLAND DRIVE MASONARY CONSTRUCTION TO BE IN ACCORDANCE WITH AS3700 ALL WET AREA FLOORS AND WALLS TO BE PROTECTED AS PER CLAUSE 3.8.1 BCA BALUSTRADING TO BE 1000MIN ABOVE FINISHED FLOOR LEVEL AND HAVE 125mm MAX SPACING IN BALUSTERS site plan PROVICE DPC'S AS PER CLAUSE 3.3.4 BCA PROVIDE FLASHINGS AS PER CLAUS 3.3.4, 3.5.1, & 3.5.3 BCA NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROPOSED: CLIENT: RON O'GRADY BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 2 of 16 DATE: ISSUE NO: RENOVATION EXTENSION PH: 0417 602 074 TBC PH: 0403 481 474 SCALE: 1:200 14 AUG 2019 P -FINAL NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
19 Viewland Drive Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.