GENERAL NOTES
70
19 viewland drive, noosa heads 4567
70 75 75 75 75
lot 8 on RP88535
2730 2725 900 2400 3605 05 of 16
elevation C
TIMBER FRAMING AND CONSTRUCTION
05 of 16 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
elevation B THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
0612OXSW 1212OXSW 0606OXSW OBS 1209OXSW OBS 1212OXSW 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
70
70
70
70
MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
1505
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
770
bath
1212OXSW
1218OXSW
2630
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
3005
3005
bed bed bed
75
900 SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
900
900
770 900 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
75
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
900
6600
store
770
770
770
600
75 600
robe robe robe 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
4175
75
75
9. BUILDER AND TRADES ARE TO CONFIRM ALL
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
1000
SETOUT AND ORDERING OF MATERIALS
9200
sitting 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
1212OXSW
store
2780
AS NO RESPONSIBILITY WILL BE TAKEN AFTER
CONSTRUCTION HAS COMMENCED
p. 11. ALL TRADES ARE TO CONFORM WITH THE
1218OXSW
dine CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
5380
HER OWN WORK
refs
70
4375
1212OXSW DN 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
820 3660.1.2000
kit
3300
0915OXSW
DOMESTIC SMOKE ALARMS
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
820
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
servery REGULATION 2016
75
70
75
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
deck WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
7000
AND INTERCOM SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
2118OXSD
150x75 hw plate
150x75 hw plate
2118OXSD
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
240x70 exposed beam
lounge
deck
elevation A
4200
4400
REMOVED FROM DEVICE
04 of 16 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
DN GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
200
block veneer end wall SUBJECT TO CONFIRMATION UPON SITE MEASURE
elevation D 2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
75 75 70 PRIVACY OPTIONS
05 of 16 2500 1000 2100 3075 3905
70 ELECTRICAL AND ENERGY EFFICIENCY
5600 70 5460 1600 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
UPPER TOP PLATE
DOWNPIPES
UPPER JOINERY LINE
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
existing upper floor
CONFIRMED AT TIME OF ROOFING CONSTRUCTION
2400
2100
AND COMPLIANCE
EXISTING UPPER FLOOR
400
GROUND TOP PLATE
GROUND JOINERY LINE
2400
2100
GROUND FLOOR
200
PAD LEVEL
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: RON O'GRADY BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 4 of 16 DATE: ISSUE NO:
RENOVATION EXTENSION PH: 0417 602 074 TBC PH: 0403 481 474 SCALE: 1:100 14 AUG 2019 P -FINAL
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
19 Viewland Drive Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.