19 Viewland Drive Final Renovation Plans Stage 16 · OPW19/0180
Attached to the e-mail Operational Works Application OPW19/0180 - DA Form 1 - Supporting information document - Plans - Plans - Arborist Report - at 19 Viewland Drive Noosa Heads.
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES 19 viewland drive, noosa heads 4567 lot 8 on RP88535 TIMBER FRAMING AND CONSTRUCTION 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH renovate bath and wc THE AUSTRALIAN DOMESTIC BUILDING CODE. and extend 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL. 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 4.HARDWOOD FRAMING TO BE MINIMUM STRESS bath GRADE F14 & MINIMUM JOINT GROUP J2. extension point for bed bed 900 bed 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. master bedroom/ensuite SPECIFICATIONS ALL OTHER FIXINGS TO BE IN 900 900 900 ACCORDANCE WITH AS 1684.2 2010 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO sitting SETOUT AND ORDERING OF MATERIALS 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED replace and resize this window as per proposed dine 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR DN HER OWN WORK make opening as external door kit 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000 remove shs post proposed l'dry replace and relocate stairs and wet area demolish shower room DOMESTIC SMOKE ALARMS 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED replace all existing windows with existing 250x150 UBx8mm Steel I Beam 2panel louvres as per proposed WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT extend deck and roof over and raise joinery height REGULATION 2016 demolish stairs replace and relocate garage door as per proposed existing 190x80 hwd bearer existing steel beam proposed support 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE build in as entry way existing 190x80 hwd bearer point to be confirmed by engineer WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL upper floor all new AND INTERCOM SYSTEMS. garage lounge 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE REMOVED FROM DEVICE 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS TO EXISTING RESIDENCES DN S INDICATES THE LOCATION OF WIRED SMOKE ALARMS GLAZING 400 demolish replace and relocate stairs 1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND remove this part l'dry demolish walls SUBJECT TO CONFIRMATION UPON SITE MEASURE of blockwork 1430 Upper Floor Demolition + Proposed 2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR PRIVACY OPTIONS 1600 600 relocate maintain 600 return block work patio hws UP ELECTRICAL AND ENERGY EFFICIENCY demolish wall 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED Demolition + Proposed replace door with larger stackers 3570 INDICATIVE ONLY proposed build in as entry (remove window and frame in demolish existing stairs UP new patio slab DOWNPIPES as per proposed ALL LOCATED DOWNPIPES INDICATIVE ONLY AND utility relocate timber posts remove replace and CONFIRMED AT TIME OF ROOFING CONSTRUCTION AND COMPLIANCE 1600 Ground Floor Demolition + Proposed NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROPOSED: CLIENT: RON O'GRADY BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 6 of 16 DATE: ISSUE NO: RENOVATION EXTENSION PH: 0417 602 074 TBC PH: 0403 481 474 SCALE: 1:100 14 AUG 2019 P -FINAL NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
19 Viewland Drive Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.