19 Viewland Drive Final Renovation Plans Stage 16 · OPW19/0180
Attached to the e-mail Operational Works Application OPW19/0180 - DA Form 1 - Supporting information document - Plans - Plans - Arborist Report - at 19 Viewland Drive Noosa Heads.
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES 19 viewland drive, noosa heads 4567 Areas lot 8 on RP88535 TIMBER FRAMING AND CONSTRUCTION Name Area 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN DOMESTIC BUILDING CODE. patio 24.50 m² 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH deck 26.43 m² AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL. upper floor 147.00 m² 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE extensions 28.44 m² MGP 10/MGP12 balcony 4.84 m² 4.HARDWOOD FRAMING TO BE MINIMUM STRESS porch 1.73 m² GRADE F14 & MINIMUM JOINT GROUP J2. rumpus 45.56 m² 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. work room 22.90 m² 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN shed 14.45 m² 10 of 16 ACCORDANCE WITH AS 1684.2 2010 l'dry 15.56 m² 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN garage 52.57 m² 200 200 200 90 90 90 TABLES WHERE OTHER BRANDS ARE USED, SIZES TO Elevation 3 - east Grand total 383.99 m² 2675 1200 2680 1100 500 BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. Elevation 2 - south 5 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 3075 200 1610 90 980 90 1690 90 3 09 of 16 9. BUILDER AND TRADES ARE TO CONFIRM ALL small block cut to match MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO hws relocated window opening with other SETOUT AND ORDERING OF MATERIALS mbox dp 04518LW dp 1512LW 1512LW dp 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER 200 200 1512LW 0906LW obs 200 AS NO RESPONSIBILITY WILL BE TAKEN AFTER 200 200 CONSTRUCTION HAS COMMENCED 495 2/720q/slide wms 11. ALL TRADES ARE TO CONFORM WITH THE existing blockwork 2403FG 1620 wall hung store CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR 2030 3480 to cut back to dryer HER OWN WORK l'dry 720 shed 820 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS (conc) 90 existing 250x150 UBx8mm Steel I Beam 04518LW 2/720q/slide existing line of post 3660.1.2000 2452 PANELIFT DOOR pdr 4700 4300 door and window within 90 90 940 4 4 530 820 shs post existing framework DOMESTIC SMOKE ALARMS line of floor over 90 l'dry chute garage 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED 6200 5210 6610 existing 190x80 hwd bearer bench+ 6600 WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE 6800 existing 190x80 hwd bearer 2400x820 cupboards existing conc WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT work REGULATION 2016 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE room 200 2424RD WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL 1512LW line of floor over existing line of l'dry AND INTERCOM SYSTEMS. 2 2 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD existing WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE window line 495 existing 75x75 shs post REMOVED FROM DEVICE 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND 90 400 1512LW 90 dp 1200csd BEDROOMS TO EXISTING RESIDENCES porch new load 2400x920 S INDICATES THE LOCATION OF WIRED SMOKE ALARMS entry 2406glass bricks conc 850 refs 1512LW 1420 point existing opening for door/window 2500 trellis 2400 GLAZING wetbar utilising 480 lin (ceramic tile) 600w 390 610 existing l'dry plumbing flo e of 1600 1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND new load wall for steel beam 3310 or glass SUBJECT TO CONFIRMATION UPON SITE MEASURE Proposed Ground Floor fin ish bricks 2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT 1785 TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR 900 90 1090 timber PRIVACY OPTIONS 610 820 treads 90 6310 ELECTRICAL AND ENERGY EFFICIENCY 2424XOSD 1000 3290 void 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER 27045FG approximate line of block (tinted) frame in existing window store 1 1 1800 1800 AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED 1910 cut to suit larger door INDICATIVE ONLY proposed ground floor 1000 UP rumpus 900 DOWNPIPES (carpet tile) ALL LOCATED DOWNPIPES INDICATIVE ONLY AND line of deck existing line 200 200 of opening 1595 1595 CONFIRMED AT TIME OF ROOFING CONSTRUCTION 2406LW 1200 Elevation 4 -north 200 90x90 timber post AND COMPLIANCE 10 of 16 stairs dp dp line of deck line of deck 90 WINDOW SCHEDULE Elevation 1 - west 200 3670 3040 200 1090 3 2x04518LW 1050 500 1050 90 1x0906LW obs 09 of 16 6x1512LW (2PANEL) 2600 90 5 1x27045FG (tinted) 2x2406 glass bricks NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROPOSED: CLIENT: RON O'GRADY BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 7 of 16 DATE: ISSUE NO: RENOVATION EXTENSION PH: 0417 602 074 TBC PH: 0403 481 474 SCALE: 1:100 14 AUG 2019 P -FINAL NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
19 Viewland Drive Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.