NOOSA COUNCIL IDAS Development Application Decision Notice 8 of 17
50. All stormwater drainage shall be collected on site and discharged so there is no net increase in
stormwater runoff from the site.
51. Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank (minimum
storage 3000 litres per dwelling/unit ) that is installed to ensure water from the tank can be used for
external uses (such as watering gardens, irrigation, ornamental ponds, water features, topping-up
swimming pools, outdoor cleaning, etc) and for use in flushing of toilets internal to the dwelling/building.
All rainwater tanks are to be designed and installed in accordance with the Queensland Development
Code (QDC), Part 25 – Rainwater Tanks, and shall be part of the plumbing application in conjunction with
the building approval. The location and capacity of the tanks shall be clearly shown on the plans
submitted for Building Works approval.
52. To ensure that polluted run-off does not enter Council’s stormwater drainage system, stormwater run-off
from the carparking areas and the driveways shall have the first flush (the first 12 mm of rainfall or hose-
down) collected in a grease/oil arrestor provided on site prior to being permitted to discharge into
Council’s drainage system.
All other clean stormwater, such as roof water, can be collected on site and discharged through a single
underground drain line directly into the existing drainage system, bypassing the grease/oil arrestor.
To this end, a detailed maintenance plan shall be prepared for the proposed grease/oil arrestors, which
shall be submitted to the Council for approval prior to obtaining a Development Permit for Operational
Works.
The approved maintenance plan shall be incorporated in the Community Management Scheme for the
development and a copy of this shall be provided for Council’s records prior to commencement of the
approved Use.
A Development Permit for Building Works shall not be granted until a Development Permit for Operational
Works has been issued in regard to the drainage scheme.
53. All site stormwater drainage shall be by means of a gravity system.
Sewer Mains
54. The site shall be connected to the Noosa Sanctuary Development sewer reticulation system and be
constructed in accordance with Council’s standards and requirements at no cost to Council.
55. All sewage shall drainage by means of gravity to the sewage pump station located on lot 2 SP110327 as
per the Deed made on 22 December 1999 between Noosa Council, Aqua Blue (Noosa) Pty Ltd and the
applicant, Johanna Jacoba Thannhauser.
56. Should the drainage via gravity not be possible a new arrangement will need to be negotiated with Noosa
Council
57. The sewer system is to be kept and maintained in a condition suitable for use and shall not cause adverse
impacts on the environment.
Town Water Supply
58. Connection to Council’s water supply shall be generally in accordance with Plan H-SP-02 drawn by Brian
Burnett & Associates dated 2007.02.12 for Aqua Blue Noosa Sanctuary Development.
59. The site shall be connected to Council’s town water supply and be constructed in accordance with
Council’s standards and requirements at no cost to Council.
60. Each individual water connection to the water reticulation system shall extend to the property boundary
and be metered. All fees for the supply of water meters shall be paid to the Council.
61. All water meters must be located in an easily assessable location to facilitate unhindered reading by
Council and/or Council’s contracted water meter readers, and not behind fences or locked gates.
62. For Multiple Uses (including Building Format Plans, Group Title Plans, etc) the development shall be
served by:
62.1. A single Body Corporate water meter to measure the total water consumption (including fire hose
reels, but excluding fire hydrants and fire sprinkler systems), and
62.2. Individual water meters to each tenement capable of being separately rated, and
62.3. A fire service (fully testable single detector check with metered bypass), where applicable, for flows
to fire hydrants and fire sprinkler systems (excluding fire hose reels).
MSOffice c:\docume~1\shesse\locals~1\temp\bcl technologies\easypdf 5\@bcl@ec126c42\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - 010.2006.00001395.001 [As Published]Related documentApplication case desk ↗