G Engineering Report And Plans · 132007.2398
Attached to the e-mail 132007.2398.02 Request to change existing approval (2 of 3) Engineering report & plans, Stormwater Plan.
Plans and drawings: the text below has words only, no drawings.
Very large file (10.6 MB): may take a few minutes to open.
CALIBRE CONSULTING
Specific Outcomes Probable Solutions Proposed Measures
(if code assessable)
O9 Sewerage Reticulation infrastructure is constructed: S9.1 Sewerage Reticulation infrastructure is constructed in Sewer infrastructure will be designed in accordance with
accordance with Section 6 of PSP 6 – Engineering Design Unity Water requirements and general engineering
(a) in accordance with appropriate engineering
Standards – Water and Sewerage and As Constructed data principles.
standards; and
submitted in accordance with Section 7 of PSP 6 –
(b) to minimise adverse environmental impacts. Engineering Design Standards – Water and Sewerage;
AND
S9.2 Erosion and Sediment control measures are designed
and implemented in accordance with the Institution of
Engineers Australia (Qld Division) Soil Erosion and
Sediment Control – Guidelines for Queensland Construction
Sites.
O10 Sewerage Reticulation infrastructure is proven to No solution provided. Sewer infrastructure will be tested and inspected to Unity
be suitable for its use prior to Council accepting the Water’s satisfaction prior to hand over.
dedicated asset.
O11 Sewerage Reticulation supply infrastructure is No solution provided. All supporting documentation will be provided during
provided with all supporting technical documentation. detailed design.
O12 Where buildings or other structures are in S12.1 The footing of any building or structure is located All existing infrastructure will be protected from the proposed
proximity to Council’s water supply infrastructure, clear of the zone of influence but no closer than 1.5m works.
provision is made to protect the infrastructure from (measured horizontally) from infrastructure including sewers,
physical damage and to allow ongoing maintenance by water mains and stormwater structures.
Council.
AND
S12.2 A registered easement in favour of Council is created
over all underground infrastructure located in private
property;
AND
B14158.W | COOROY RETIREMENT COMMUNITY | PALM LAKE RESORTS CIVIL ENGINEERING REPORT | 37
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
G ENGINEERING REPORT AND PLANS.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.