Original source · versioned page text
Appendix 3 - Traffic Engineering & Parking Report (00012497)
Attached to the e-mail MCU15/0053 Application Forms 1 & 5 and Town Planning Report - Multiple Dwellings Type 4 - Conventional at 30-32 Doonella Street Tewantin (1 email of of 3).
Photograph 2 – View from proposed access looking east.
Figure 3.3 of AS2890.1 provides minimum sight lines for pedestrian safety at
driveway accesses. To provide safe passage to pedestrians and cyclists on the
pathway, sight lines must be maintained between the property boundary and the
driveway as shown in Figure 3 below.
Figure 3– Sight Visibility Requirements
For Pedestrians and Cyclists at Driveways
The proposal complies with the requirements and the sight triangles are clear of
permanent obstructions. It is recommended that any vegetation or landscaping
treatments located within the sight triangles remain below 1.0m in height so as
driver eye height is unobstructed.
RoadPro Development ABN 98 615 073 565
14514 Doonella Street TEWANTIN Page 5 of 7