60.    The following steps are to be undertaken prior to commencement of any construction:-
  --




       60.1~ ThePri~-~ip~1 C~~tr~~to~shall gi~e-- 60-undl’~ -1~sp~ct~r--~~v~~(7)d~y~’ ~~tic~-~f----
                                                                                                   .



                intention to commence works.

       60.2. The      Principal Contractor or any of his subcontractors shall not undertake any
                works    unless each contractor has public liability insurance in the sum of
                $10,000,000 and copies of current public liability insurance policies are submitted
                to Council’s inspector.

       60.3. The Principal Contractor shall nominate a site representative and give a telephone
                number that can reach the site representative at any time during a 24 hour day.

       60.4. The site representative shall arrange to meet on-site with Council’s Inspector to
            .




             obtain Council’s requirements for construction of access.

       60.5. All signage, including that for safety during construction, shall be in accordance
             with the Manual of Uniform Traffic Control Devices and Department of Transport
                (Main Roads Division) Roadworks Signing Guide.
61.    Prior to excavating any material to be used for fill on this development site, a
       Development Permit for Operational Works shall have been obtained for the site from
       which the excavated       material is   won.   A soil   report shall be submitted with the
       application certifying that the material is free of acid sulphate soils and other deleterious
                                                                                               .




       materials.

62.    The transportation of all materials to and from the development site shall be undertaken
       in   a   manner   such that  particle matter escapes onto a public road. All vehicles
                                     no

       carrying materials either to or from the development site shall be covered to prevent
       materials inciuding dust being \~/indblown from the vehicle.

63.    A programme of works is to be .submitted with any application for a Development Permit
       for Operational Works detailing the construction schedule and proposed prevention
       measures.


     Where the program is changed for any reason whatsoever, a copy of the revised
  /’-pr:ogram shall be submitted to Council’s Works Inspector within seven (7)days.

64.    Operational Works are to be carried outin a manner that prevents:-
       64.1. Pollution of a waterway

       64.2. Dust nuisance to residents in the vicinity

       64.3. Transfer of dirt and debris onto a public road

       64.4. Excessive noise (less than 1.5 Db above ambient measured at the lot boundaries)

       64.5. Excessive traffic delays (less than 5 minute delays)

       64.6. Diminishing of neighbourhood amenity (long term parking of employees vehicles,
                parking of construction equipment etc.
65.   Where Operational Works are likely to affect nearby residents, at least 3 days notice of
      commencement ()f work, the name of the site supervisor, and             a   24 hour contact
      telephone number shall be distributed to affected residents.
66.   All designs for engineering works involving the construction of pavements, kerb and
      channel, vehicular access, footpaths, turnouts, stormwater drainage or water supply,
      shall be prepared in accordance with the requirements of Council’s Engineering Design
      Standards, shall reference where applicable to Council’s Standard Drawings, and shall
      incorporate best engineering practice.

Used in these records

About this file

File size
13.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Request change to an approval 152004.240078.4.pdf · 13.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.