Response to Further Advice · MCU22/0139
Response
In relation to Item 1, as acknowledge during our telephone conversation, Council is in receipt of a survey plan
for the property.
In relation to Item 2, please see attached amended architectural plans (Rev 6), which provide two
north/south sections that illustrate the building height and finished levels in relation to the existing natural
ground and adjoining sites. The proposed building is fully compliant with height and setback requirements.
In relation to Item 3, please see attached amended architectural plans (Rev 6), which include shadow
diagrams that demonstrate the building will not unreasonably diminish solar access to the adjoining
properties. Further, the proposal provides fully compliant height and setbacks and would be consistent with
the bulk and form for a dwelling house that could be established on the premises as ‘accepted
development’.
Issue – Setback
Acceptable Outcome AO12.1 of the Medium Density Residential Zone Code requires building and structures to
be setback a minimum of 6 metres from the frontage. Acceptable Outcome AO16 of the Medium Density
Residential Zone Code also require basements to not encroach into building setback areas.
The proposal appears to include structures approximately 3 metres high within the front setback. The
proposed basement also intrudes into the southern side boundary setback with the operational works plans
(not part of this application) detailing structural CFA piles in the setback areas.
Information Required
4. Provide further plans that demonstrate the extent of structures within the front setback. The plans are to
specifically detail the height of the stairs and surrounding retaining walls and fences and demonstrate
that they do not impact on the amenity of the area.
5. Provide revised plans that detail the basement outside of the side setback. All operational works plans
are to demonstrate no permanent piling structures in the required setback areas.
Response
In relation to Item 4, please see attached amended architectural plans (Rev 6), which illustrate the extent of
structures in the front setback. The landscaped pathway has been redesigned to provide a softer
appearance and setback from the driveway. The only structure within the 6m setback will be the retaining
wall associated with the basement entry, which has a maximum height of approximately 1.5m above the
ground level and has been softened with landscaped plantings.
In relation to Item 5, the setback of the basement along the southeast side boundary has been increased to
750mm to its outermost projection as agreed during our telephone conversation. This would ensure that the
600mm strip of landscaping along the southeast side boundary was access to deep soils. The remainder of
the setback area comprises a pathway to the washing area and rear of the site and would not need a deep
soil below.
Issue – Roof Terrace
Acceptable Outcome AO19.2 of the Medium Density Zone Code requires developments to not include rooftop
terraces. Acceptable Outcome AO12.1 of the Medium Density Residential Zone Code also requires building and
structures to be setback a minimum of 2.5 metres where above 7.5 metres height. The architectural plan details