31.

32.

33.

34.

35.

36.

37.

38.

39.

40.

41.

42.

43.

44,
45.

Any windows opening into the pool enclosure must be protected in accordance with clause 2.7 of AS1926.1.
Direct access via doorways is prohibited.

Direct access to the pool enclosure from a patio, balcony or the like is only permitted if one of the sides is
permanently open (not fitted with blinds, insect screening, shade cloth or the like).

Where the swimming pool is constructed closer than 1.5m to the property boundary a solid fence must be
constructed to prevent water entry onto adjoining lots. The fence must be at least 1.8m high above finished
ground level (but not greater than 2m above natural ground level), erected between the swimming pool and
the boundary of the lot; and the top of the wall/fence must be at least 1.0m above the top of the coping of the
pool.

All building work must be carried out in accordance with the Building Act 1975, the Building Regulation 2006,
the Queensland Development Code, and the National Construction Code and relevant Australian Standards.
All building work is to be carried out within the boundaries of the property. Where work is proposed in close
proximity to the boundaries, it may be necessary to have a cadastral surveyor identify the boundary alignment.
The pool fence and gates must be designed and constructed in accordance with the provisions of Chapter 8 of
the Qld Building Act 1975, Part 4 of the Building Regulation 2006, the Queensland Development Code Part
MP3.4 and the appropriate parts of Australian Standards AS 1926.1-2007 & 1926.2-2007.

A warning sign must be displayed in accordance with Section 14 Building Regulation 2006. The sign must
warn members of the public that a swimming pool is under construction on the property and there is a potential
danger to young children accessing the land (e.g. Danger. Swimming pool under construction. Keep children
out). The sign must be displayed on the land before the construction of the swimming pool starts, and until a
final certificate has been issued.

A resuscitation sign must be installed in accordance with Section 13A of the Building Regulation 2006. It must
be attached to the barrier for the pool, or displayed near the pool, so that the sign is conspicuous and easily
visible to a person near the pool.

Prior to commencing work, the builder must locate all infrastructure services (i.e. sewer & stormwater mains)
and easements on the property, and ensure the required setback clearances will be provided.

For swimming pools located in sewered areas or near stormwater mains, the outer part of the pool must be
located no closer than 1.2m to the pipe, and be founded below the zone of influence.

Where it is necessary to alter the existing house drainage (domestic sewer), a licensed Plumbing & Drainer
must undertake the work and obtain the relevant approvals.

Building work over or adjacent to existing sanitary drainage must comply with AS/NZS 3500.2.2-1996
(National Plumbing and Drainage), Part 2.2 (Sanitary Plumbing and Drainage — Acceptable Solutions).
Drainage around the pool must be in accordance with the requirements of the design engineer. Surface water
drainage must not be directed towards other buildings or onto neighbouring allotments.

The water recirculation system of the swimming pool must comply with AS1926.3-2010.

If the filter installed produces backwash, the backwash must be discharged to the sewer.

 

 

7 AVOCET PARADE, PEREGIAN BEACH
PERMIT NO 8140 PAGE 4 OF 6

 

 

Used in these records

About this file

File size
16.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

7 avocet pde.pdf · 16.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.