24647 Seaview Tce Enviro Mgmt Plan

Attached to the e-mail MCU14/0084 Environmental Management Plan (71 Seaview Tce).

of 212

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (18.0 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
                                                                                                    EWSM- 1 EROSION AND SEDIMENT CONTROL (STORMWATER MANAGEMENT)
                                                                                                                                                          Version 1


Hierarchy of Control (HOC): 1. Eliminate 2. Substitute 3. Isolate 4. Engineer 5. Admin 6. PPE

Work platforms connected to the    Concentrated flow might cause          5      Roof water downpipes (temporary or permanent) should be                    Hutchinson Builders
stormwater system shall be         erosion                                        connected to the stormwater drainage system immediately after the          Foreman
maintained in good order and                                                      roof is laid.
cleaned frequently of
sediment/debris which may enter                                                                                                                              Workers
the system                         Inappropriate and ineffective          5      Sediment control devices must be de-silted and made fully                  Hutchinson Builders
                                   sediment control measures                      operational as soon as reasonable and practicable after a sediment-        Foreman
                                                                                  producing event, whether natural or artificial, if the device's sediment
                                                                                  retention capacity falls below 75% of its design retention capacity.
                                                                                                                                                             Workers


                                   Inappropriate and ineffective          5      Sediment fence is buried in 200mm deep. Along the lower side of the        Hutchinson Builders
                                   sediment fence                                 trench, appropriately secure the stakes into the ground spaced no          Foreman
                                                                                  greater than 3m if supported by a top support wire or weir mesh
                                                                                  backing, otherwise no greater than 2m
                                                                                                                                                             Workers
                                                                                 In areas where it is impractical to bury the lower edge of the sediment
                                                                                  fence, the lower 200 mm (min) portion of the fabric should be placed
                                                                                  on the ground up-slope of the fence and buried under a 100 mm (min)
                                                                                  layer of coarse aggregate (20-40 mm)
                                                                                 Sediment fences should be located down-slope of the disturbance,
                                                                                  and ideally along a line of constant land level to prevent the
                                                                                  concentration of stormwater run-off. Where this cannot be achieved
                                                                                  then sections of the sediment fence should have ‘returns’ directed up
                                                                                  slope for 1-2 metres to control the concentration of stormwater run-
                                                                                  off
                                                                                 Replace sediment fences if the fabric is ripped or otherwise damaged.
                                                                                  The maintenance of sediment fences includes the removal of
                                                                                  sediment deposited up-slope of the fence and, where necessary, re-
                                                                                  trenching the fabric and ensuring posts are firmly secured in the
                                                                                  ground                                                                     HSE Advisor
                                                                                 If excessive sediment build-up occurs, reapply crushed rock to the
                                                                                  entry/exit pad.
                                                                                 Daily check on sediment fence
Trenching                          Sediment-laden water ponding on       5       No more than 150m of a stormwater, sewer line or other service             Site Manager
                                   site                                           trench must to be open at any one time.
                                                                                 Where it is practical, trench needs to be backfilled when the
                                                                                  significant event is forecasted




                                                                                                                                                                                   3
Log in to download the original file

24647 Seaview Tce Enviro Mgmt Plan.pdf · 18.0 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.