    Noosa Iconic Panel                                                   Decision Notice - Development Permit
                                                                       Material change of use - detached house
                                                                                  6 Allambi Rise, Noosa Heads
                                                                                                28 August 2009

    Building Height
    8.    The building height shall not exceed 8.0 metres above the natural ground level, finished
          ground level and 2 storeys.
    9.    A verification survey of the building is to be carried out by a Licensed Surveyor and a certificate
          lodged with Council at completion of the work confirming compliance with the maximum
          allowable building height as required by either the conditions of approval of the Planning
          Scheme.
    Landscaping
    10.   A minimum of 20% of the site shall be retained as soft landscaping.
    11.   Existing trees within the road reserve shall be retained.
    12.   One Koala food tree shall be planted within the road reserve in accordance with Council's PSP
          3 Landscaping Plants and Guidelines.
    13.   Existing trees on the site shall be retained, except where required to be removed due to
          building operations or the conduct of the approved use.
    14.   All other vegetation shall be protected from interference resulting from clearing or construction
          activities by:
          14.1.   Clearly marking vegetation to be retained with flagging tape;
          14.2.   Installing protective fencing around the drip line of the vegetation;
          14.3.   Stockpiling, storage and vehicle parking occurs in already cleared areas and does not
                  cause interference with vegetation; and
          14.4.   Low impact construction techniques are used around vegetation to minimise
                  interference with the vegetation
    15.   Cleared vegetation is to be suitably processed by one of the following methods and removed
          from the site:
          15.1.   Processing through a woodchipper or shredder. The resulting mulch is to be stockpiled
                  loose in heaps of less than 1000 cubic metres, less than 2.5 metres high with a
                  minimum of 10 metres between edges of heaps.
          15.2.   Disposal for firewood.
          15.3.   Disposal for landscaping purposes.
          15.4.   Transport to alternative site for breaking down materials provided that all necessary
                  permits have been obtained to allow the alternate site to be used for this purpose.
          15.5.   The applicant is advised that burning off is an unacceptable method of disposal
    Frontage Works
    16.   All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel,
          footpath paving and landscaping such as trees and grasses in accordance with Council's
          Standard specifications prior to commencement of the use permitted by this permit.
    Roof Water & Stormwater Drainage
    17.   Roof runoff from any new building shall be directed to a rainwater storage system or tank that
          is installed to ensure water from the rainwater storage system or tank is used for external uses
          (such as watering gardens, irrigation, ornamental ponds, water features, topping-up swimming
          pools, outdoor cleaning, etc) and for internal (ground floor) use in washing machine cold taps
          and toilet cisterns. All rainwater tanks are to be designed and installed in accordance with the
          Queensland Development Code (QDC) current at the time of building approval, and shall be
          part of the plumbing application for approval.
          The location and capacity of the tanks shall be clearly shown on the plans submitted for
          Building Works Approval and any overflow shall be directed to Council's kerb and channel
          system in Allambi Rise.




                                                                                           Page 3 of 7

Used in these records

About this file

File size
4.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Change to an Existing Approval-132009.325.01.pdf · 4.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.