B - Code Compliance

of 99
Waterways Works Code

e) materials blend with the natural surrounds;            i.        are setback a minimum of 1 metres from the
f) cluttering of watercourses is avoided;                           prolongation of the boundaries;
g) excessive traffic volumes within foreshore areas,       ii.      are not more than 1.5 metres in width;
   on adjoining lands and in the water are avoided;       iii.      have no jetty head;
   and                                                    iv.       allow for safe access and manoeuvrability of
h) they reflect the character and setting of the                    vessels for both the neighbouring property and
   work’s immediate surrounds of the locality.                      the subject property; and
                                                           v.       are not constructed on sites where there is an
                                                                    existing shared jetty on either prolongation of the
                                                                    side property boundaries.
                                                        AO16.3
                                                        For lots that adjoin those described in AO16.2, the jetty
                                                        is located well away from the common boundary.
PO17                                                    AO17                                                            PO17 – Not Applicable
Landings are not roofed.                                No acceptable outcome provided                                  The development does not include Prescribed Tidal
                                                                                                                        Works.
Design, Construction and Safety for Jetties within Noosa Waters Estate waterways
PO18                                                    AO18                                                            PO18 – Not Applicable
Structures such as handrails, light bollards, piers and No acceptable outcome provided.                                 The development does not propose jetties within
pumping equipment for semi-submersible floating                                                                         Noosa Waters Estate waterways.
docks have a maximum height of 1100mm above
the jetty floor.
PO19                                                    AO19.1                                                          AO19.1 to AO19.9 – Not Applicable
Development is designed and constructed for the Jetties—                                                                The development does not propose jetties within
sole purpose of providing access to vessels and are a) are a maximum width of 1.5 metres;                               Noosa Waters Estate waterways.
sited and designed to avoid—                            b) a maximum length of a jetty head is not more than 7
a) cluttering of waterways;                                    metres (Refer Figure 9.4.9.3C);
b) excessive traffic volumes within foreshore areas, c) constructed predominantly of timber;
     on adjoining lands and within the waterway; and d) are not constructed parallel to the revetment wall;
c) unacceptable risks to personal and public safety.           and extend a maximum of 10 metres past the
                                                               quayline.
                                                        AO19.2
                                                        For “Y” and “T” shaped jetty heads or other shaped jetty
                                                        heads—
                                                        a) a maximum area of 10.5m² excluding any walkway
                                                               is provided; and

Log in to download the original (B - Code Compliance.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.