OilSET-1000 Oil Separator Alarm Device                                                             D15383Be
Installation and Operating Instructions


5   REPAIR AND SERVICE

                              The probe should be cleaned and the operation should also be tested
                              when emptying the oil storage chamber or at least once every six
                              months. The easiest way to check the operation is to lift the probe up
                              in the air and to put it back to the separator. The operation is
                              described in chapter 3.
                              For cleaning, a mild detergent (e.g. washing-up liquid) and a
                              scrubbing brush can be used.
                              The mains fuse (marked 125 mAT) can be changed to another glass
                              tube fuse 5 x 20 mm / 125 mAT complying EN 60127-2/3. Any other
                              repair and service works on the device may be carried out only by a
                              person who has received training in Ex-i devices and is authorized by
                              the manufacturer.
                              In case of queries, please         contact   Labkotec     Oy’s   service:
                              [email protected]   SAFETY INSTRUCTIONS

                              OilSET-1000 control unit must not be installed in potentially explosive
                              atmosphere. Probes connected to it may be installed in zone 0, 1 or 2
                              potentially explosive atmospheres.
                              In case of installations in explosive atmospheres the national
                              requirements and relevant standards as EN 50039 and/or EN 60079-
                              14 must be taken into account.
                              If electrostatic discharges can cause hazards in the operating
                              environment, the device must be connected into equipotential ground
                              according to requirements with regards to explosive atmospheres.
                              Equipotential grounding is made by connecting all conductive parts
                              into same potential e.g. at the cable junction box. Equipotential ground
                              must be earthed.
                              The device does not include a mains switch. A two pole mains switch
                              (250 VAC 1 A), which isolates both lines (L1, N) must be installed in
                              the main power supply lines in the vicinity of the unit. This switch
                              facilitates maintenance and service operations and it has to be marked
                              to identify the unit.
                              When executing service, inspection and repair in explosive
                              atmosphere, the rules in standards EN 60079-17 and EN 60079-19
                              about instructions of Ex-devices must be obeyed.




Copyright © 2010                                   9/10          We reserve the right for changes without notice
Log in to download the original file

Appendix C - Stormwater Management Plan.pdf · 6.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.