Council archive · source document
Attachment 2 - Goodchap Street Operational Works · 132007.12.8
Attached to the e-mail 132007.12.8 - Response to Information Request.
2009/538 10. 11. 412. The plan should detail the routing of trucks to and from the site. Provision of onsite parking for personnel working on this development, as there is limited parking available in adjacent streets. d. Provision of safe cycle and pedestrian movements in the vicinity of the development. e. No queuing of trucks is permitted on residential. streets, especially prior to 7.00am. Further parked trucks must have engines turned off. f. Provision of signage and traffic controllers in accordance with Manual of Uniform Traffic Control Devices and the Transport Infrastructure (Roads) Act. The total required pavement thickness shall be based on the Department of Main Roads’ Pavement Design Manual using soaked CBR tests of the subgrade. The new driveway crossovers shall be constructed in accordance with Council's Standard Drawing SEQ R-050 Rev A (Residential Driveway). Suitable root barriers shall be installed (where applicable) where trees are adjacent to paths, . pavement, etc; in accordance with Council’s Planning Scheme Policy PSP03 Landscaping Plants and Guidelines. Suitable sediment control devices shall be temporarily installed into the first existing external downstream stormwater structure. These devices are to be checked and cleaned on a regular basis and specifically after each rain event. These devices are to remain in place during the civil works and construction phases of the project. The location and type of device to be installed shall be established at the "pre start” meeting : with Council’s Construction Technical Officer and shall be installed prior to the commencement of any works. A site contro! and/or compliance bond of $5000 is to be submitted to Council prior to the pre- start meeting. The pre-start meeting will only be held once Council's Construction Technical Officer has confirmation that Council has received the bond monies. The bond will be refunded less any costs incurred by Council in ensuring compliance with these conditions or any additional inspections incurred for substandard work or work undertaken not in accordance with this permit. Council’s Construction Technical Officer (phone 0439 717 952) shall be given seven (7) days’ notice of intention to commence works to arrange a “pre start” meeting prior to the commencement of those works. The principal contractor must have all the appropriate insurance and public liability documentation to carry out the works. The principal contractor is also responsible to ensure that any subcontractors also have the appropriate insurance and public liability documentation. Prior to the “pre start” meeting, the principal contractor must be provided with a copy of Council's signed approved drawings and conditions by the applicant. The Consulting Engineers for the project shall be currently Registered Professional Engineers of Queensland (RPEQ). The Consulting Engineers are responsible for arranging all inspections with Council's Construction Technical Officer or nominated staff. Council's Construction Technical Officer shall provide an inspection form for signing-off by the Engineer at appropriate stages of construction during on-site meetings. The Construction Technical Officer will also sign the form at each stage when requested conditions have been satisfied. The works will be accepted “On Maintenance” after this form has been signed by the Construction Technical Officer for each stage, and a letter from the Engineer has been received by Council requesting that the works go “On Maintenance”. Page 2 of 7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 2 - Goodchap Street Operational Works.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.