    46.   A bin wash area is required with a cold-water tap, hose and drain outlet connected to
          sewer, via a bucket trap. The drain outlet is to be designed to prevent storm water entry
          to the sewerage system which can be achieved by a bunded area, with a nib wall height
          of 100mm maximum, enclosing a wash area of 700mm x 700mm minimum (max
          0.7m²). Alternatively, the waste area can be roofed, or any other appropriate design
          approved by Council.
          Noise
    47.   Written certification is required from a suitably qualified person confirming that sound
          pressure levels from all mechanical plant and equipment comply with the following:
          a.    Air-conditioning and Refrigeration
                •       7am to 10pm: Maximum level allowable = background + 5dB(A)
                •       10pm to 7am: Maximum level allowable = background + 3dB(A)
          b.      Pumps
                •       7am to 7pm: Maximum level allowable = background + 5dB(A)
                •       7pm to 10pm: Maximum level allowable = background + 3dB(A)
                •       10pm to 7am: No audible noise.
    48.   The certification must be submitted to Council, which certifies that operational noise
          from any fixed plant and equipment complies with the requirements of this Decision
          Notice.
    Kitchen Exhaust (Food and drink outlet)
    49.   Kitchen exhaust points for the Food and drink outlet must be located and operated in
          accordance with Australian Standard AS1668.2-2002 “The use of ventilation and air-
          conditioning in buildings” (specifically Section 5.10 – Air Discharges).
    50.   The development must be constructed with reticulated ducting inside the building to
          transfer kitchen exhaust fumes to a discharge point on the roof.
    51.   Submission of written certification must be provided from a suitably qualified person
          confirming that the kitchen exhaust is constructed, installed and is operating in
          accordance with Australian Standard AS1668.2-2002.
    52.   The assessment and certification is required immediately after installation of the
          equipment and prior to any occupation of the building, and in a format approved by
          Council.
    Outdoor Lighting Devices
    53.   Lighting associated with the use must be designed, sited, installed and tested to comply
          with Table 2.1 & 2.2 of Australian Standard AS4282-1997 “Control of the obtrusive
          effects of outdoor lighting” using a control level of 1.
    54.   Certification must be submitted to Council from a qualified person which certifies that
          all outdoor lighting devices comply with the requirements of this Decision Notice at the
          time of commissioning.
          For the purpose of certifying outdoor lighting devices for the development, a qualified
          person is:
           a.       a Registered Professional Engineer of Queensland;
           b.       an environmental or electrical design consultant with a minimum of 3 years
                    current experience in the field of outdoor lighting.
    LANDSCAPING
    55.   The development site must be landscaped. The works must be undertaken in

                                                                                   Page 16 of 26
Log in to download the original file

2022-02-14 General Committee Meeting Minutes(PDF, 373KB).pdf · 382 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.