                      Site Access and Driveways
               20.    A sealed access driveway must be provided from William Street to all parking and
                      manoeuvring areas of the development. The works must be undertaken in accordance with
                      the conditions of this approval, be generally in accordance with SCG Consulting’s
                      Operational Works Driveway & Access Plan (00461-OW4.1) and Operational Works
                      Driveway Details (00461-OW4.2) dated April 2025 and must include in particular:
                      a.      A driveway crossover in accordance with Council standard drawings RS-049 and RS-
                              050 and any associated addendum.
                      Car Parking
               21.    A minimum of 6 car parking spaces must be provided and marked on the site. The works
                      must be undertaken in accordance with an Operational Works approval and must include in
                      particular:
                      a.      1 visitor parking spaces within the total, which are clearly marked for that purpose and
                              accessible at all times for visitor use;
                      b.      dimensions, crossfalls and gradients in accordance with Australian Standard AS2890:
                              Parking Facilities
                      Stormwater Drainage
               22.    The site must be provided with a stormwater drainage system connecting to a lawful point of
                      discharge. The works must be undertaken in accordance with the conditions of this approval
                      and be generally in accordance with SCG Consulting’s Operational Works Stormwater
                      Management Plan Basement Level (00461-SW1.1) and Operational Works Stormwater
                      Management Plan Ground Level (00461-SW1.2) dated April 2025.
                      Services
               23.    Reticulated electricity and telecommunication services must be provided to each lot/unit in
                      accordance with an approval for Operational Works and the standards and requirements of
                      the relevant service provider.
               24.    Unless otherwise stipulated by telecommunications legislation at the time of construction, the
                      development must be provided with all necessary conduits, pits and pipes to accommodate
                      the future connection of optic fibre technology telecommunications.
               25.    Certification must be submitted to Council from all relevant service providers (Energex, NBN
                      and Unitywater) which certifies that the development has met the requirements of this
                      Decision Notice and all applicable legislation at the time of construction.
                      Earthworks and Retaining Walls
               26.    All earthworks and associated retaining structures/batters, both above and below ground,
                      both temporary and permanent, must be undertaken in accordance with the conditions of this
                      approval, be generally in accordance with SCG Consulting’s Operational Works Earthworks
                      Plan (00461-OW3.1) , Operational Works Earthworks Sections Sheet 1 (00461-OW3.2) and
                      Operational Works Earthworks Sections Sheet 1 (00461-OW3.2) dated April 2025 and
                      contained entirely within the subject site unless written permission from the respective
                      landowner(s) is provided to Council.
               27.    All retaining walls must be designed and constructed in accordance with the planning scheme
                      and must be certified by an RPEQ where exceeding 1.0m in height. All retaining walls that
                      are publicly accessible and exceed 1.0m in height must be fitted with a commercial grade
                      safety fence.
                      Acid Sulfate Soils
               28.    All works must be carried out in accordance with updated site-specific Acid Sulfate Soil,
                      Groundwater and Dewatering Management Plans.
                      *(Refer to Advisory Note)

                                                                                                        Page 5 of 21

Document Set ID: 24062787
Version: 1, Version Date: 27/08/2025

Used in these records

About this file

File size
184 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Delegated Planning Report Conditions - Approval (As Publihed).pdf · 184 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.