Appendix B - New Dwelling Plans
Plans and drawings: the text below has words only, no drawings.
Original PDF page 7, section 1. The text section number identifies this passage in the reader.
Q.D.C. MP 4.1 SUSTAINABLE BUILDINGS - ENERGY EFFICIENT DOMESTIC SERVICES
* ENERGY EFFICIENT LIGHTING * TOILETS
CLASS 1 BUILDINGS, INCLUDING A VERANDAH, BALCONY IN AREAS SERVICED BY A WATER SERVICE PROVIDER, ALL
OR AN ENCLOSED CLASS 10a BUILDING ATTACHED TO A TOILET CISTERNS:
CLASS 1 BUILDING, HAVE: (a) HAVE A DUAL FLUSH FUNCTION AND HAVE A
(a) ARTIFICIAL LIGHTING THAT COMPLIES WITH PART MINIMUM 4-STAR WATER EFFICIENCY LABELLING
3.12.5.5 OF BCA 2010 AND STANDARDS RATING; AND
(VOLUME 2); or (b) ARE COMPATIBLE WITH THE SIZE OF THE
(b) ENERGY EFFICIENT LIGHTING FOR A MINIMUM OF TOILET BOWL TO ALLOW FOR PROPER FUNCTIONING
80 PER CENT OF TOTAL FIXED ARTIFICIAL LIGHTING. OF THE TOILET.
25°
25° * HOT WATER SUPPLY * TAP WARE
A WATER HEATER IN A HOT WATER SUPPLY SYSTEM CAN BE IN CLASS 1 AND CLASS 2 BUILDINGS, IN AREAS SERVICED
RAFTERS SIZED & TIED DOWN AN ELECTRICAL RESISTANCE HEATER OR ANY OTHER TYPE BY A WATER SERVICE PROVIDER, TAP WARE WITH A
OF HEATER. MINIMUM 3- STAR WATER EFFICIENCY LABELLING AND
TO ENGINEERS' DETAILS
STANDARDS RATING SERVES:
* SHOWER ROSE (a) LAUNDRY TUBS; AND
(b) KITCHEN SINKS; AND
IN AREAS SERVICED BY A WATER SERVICE PROVIDER, ALL
(c) BASINS.
SHOWER ROSES HAVE A MINIMUM 3-STAR WATER
EFFICIENCY LABELLING AND STANDARDS RATING.
GF CL POWDERCOATED ALUM. WINDOW & DOOR FRAMES
2700 GF WH
2400
NOTES:
TERMITE PROTECTION IS TO BE PROVIDED IN
GAMES-BAR FAMILY-DINING KITCHEN WIP WIR ACCORDANCE WITH NCC VOL 2, 3.1.4
AND AS 3660.1.
PROVIDE A STATEMENT OF PROTECTION METHOD
GF FL FROM A TERMITE MANAGEMENT PROFESSIONAL IN
0 CONJUNCTION WITH THESE DRAWINGS AT THE TIME
R.CONC. FOOTINGS TO ENGINEERS' SPECS.
OF SUBMISSION FOR BUILDING APPLICATION
APPROVAL
SECTION A
A 1 : 100
ALL WET AREAS TO BE CONSTRUCTED TO COMPLY
WITH THE NCC VOL 2, PART 3.8.1
BUILDER TO ENSURE THAT FALLS, WATER STOP
ANGLES, BOND BREAKERS & HOBS ARE IN
ACCORDANCE WITH AS 3740
REFER TO ENGINEERS DETAILS FOR HOLD DOWN &
BRACING PLANS, ALL STEEL/TIMBER SIZING & FIXING
COLORBOND ROOF SHEETING
DETAILS, SLAB & FOOTING DETAILS AND LINTEL
FIXED TO MANUF. SPECS.
25° SIZING & FIXING
ROOF BATTENS SIZED, SPACED & FIXED
TO ENGINEERS' DETAILS. WASTEPIPE SETOUT DIMENSIONS ARE APPROXIMATE.
SEE MANUFACTURER DETAILS.
GANGNAIL TRUSSES TIED DOWN
SELECTED INSULATION IN ACCORD. TO TRUSS MANUF. ENGINEERS DETAILS DOOR REBATES SETOUT DIMENSIONS ARE SUBJECT
ROOF BEAMS TO ENGINEERS' DETAILS
WITH ENERGY EFFICIENCY REPORT TO DOOR MANUFACTURER DETAILS
(WALLS, ROOF &/or CEILING) CEILING BATTENS @ 450mm CTRS.
GF CL VANITY FLOOR WASTES ARE IN WALL FRAMES
2700 GF WH 10mm PLASTERBOARD CEILING & WALL LINING COLORBOND FASCIA & GUTTERS (VANITIES ARE WALL HUNG)
2400
TIMBER FRAMES TO ENG. DETAILS F.C EXT. CEILINGS & SOFFITS PUDDLE FLANGES TO BE INSTALLED CORRECTLY TO
140x140 MERBAU POSTS SHOWERS (ALLOW NATURAL FALL)
ON GAL. STIRRUPS ALFRESCO BED 1 GARAGE MASONRY TIES TO NCC 3.3.5.10 & AS/NZS 2699.1
TIE-DOWN & BRACING AS PER ENG. SPECS.
GF FL 100mm CONC. SLAB SELECTED FACE & SILL BRICKS.
0
SECTION B
B 1 : 100
SLAB & FOOTINGS TO ENGINEERS DETAILS
© COPYRIGHT. THIS DRAWING REMAINS THE PROPERTY OF G.J GARDNER HOMES & IS PROVIDED FOR THE USE AS DESCRIBED & MAY NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. ANY LANDSCAPING (WHEN SHOWN) ARE FOR ILLUSTRATIVE PURPOSES ONLY AND DO NOT FORM PART OF ANY CONTRACT.
PAGE: SHEET SIZE: REV DRN CHK DETAILS DATE: I/WE HAVE CHECKED THE PLANS AND AGREE THAT
MONTVILLE 462 ASPECT HOUSE
CLIENT: PROJECT: PROPOSED RESIDENCE 7 A3 * RW RW CONCEPT FLOOR PLAN 28/06/22 THEY ACCURATELY DEPICT THE HOUSE FOR
CONSTRUCTION.
SANDRA & RICHARD MATHISON JOB NUMBER: B RW RW AMENDED CONCEPTS 03/08/22
(MODIFIED) PLANS LOT 2 ON RP196994 GJGG430718 C RW RW AMENDMENTS - PRELIMS 29/09/22 JOB SPECIFICATION BY BUILDER TAKES
PRECEDENCE OVER THESE PLANS.
WOJTEK STAINWALD RESORT FACADE 1073 POMONA - KIN KIN ROAD SALESPERSON: D RW RW AMENDMENTS - PRELIMS 01/11/22
DRAWING TITLE:
QLD QLD KIN KIN, QLD CHRIS McNEIL E RW RW AMENDMENTS - PRELIMS 21/12/22 OWNER SIGNED: ............................... DATE: ..........
© COPYRIGHT EXCLUSIVE DATE: F RW RW CONSTRUCTION DRAWINGS 04/05/23 OWNER SIGNED: ............................... DATE: ..........
QBCC 1285235 TO G.J.GARDNER HOMES QBCC 1257937 SECTIONS/QDC NOTES 13/07/2023 G RW RW GARAGE BIGGER 13/07/23 BUILDER SIGNED: ............................. DATE: ..........
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.