Code Assessment - 12 Eenie Creek Rd (RESOLVED DRAFT)

of 64

Page text shows just the words. Original shows the document exactly as it was published.

PO5                                      No acceptable outcome provided
                                                                                 Not applicable
Development for caretaker’s
                                                                                 No caretaker's accommodation is
accommodation: (a) is directly
                                                                                 proposed.
associated with and subordinate to
the industry activity on site; (b)
demonstrates a demand for 24 hour
care of buildings, operations, plant
or equipment; (c) is not separately
let for other accommodation
activities; (d) is limited to 1
caretaker’s accommodation for
every 1,000m² of non­residential
gross floor area; (e) only located
with a large scale activity; (f) has a
maximum gross floor area of 65m2
and (g) is occupied by at least one
person who is employed by the
primary non­residential use on­site.
Venture Drive Enterprise Precin

PO6                                      AO6
                                                                                 Not applicable
Theatres are for the production of       The filmmaking studio or a music
                                                                                 No theatre, filmmaking studio or music
film or music only and do not create     recording studio is not within 50
                                                                                 recording studio is proposed.
adverse off site impacts regarding       metres of a sensitive land use.
noise, light, vibration, odour or dust
on adjoining residential
development.

PO7                                      AO7
                                                                                 Complies with PO
Trade related offices are small scale,   Office uses are trade­related, do not
                                                                                 No standalone office use is proposed. The
do not compromise or compete             exceed 15% of the gross floor
                                                                                 amenities and offices shown on sheet
with the Noosa Shire Centres             Acceptable Outcomes
                                                                                 A202 are ancillary to the showroom use,
Hierarchy, are developed area of the
                                                                                 are internal to the existing building, and
development and support the
                                                                                 are not a trade related office use in their
industry activity on site. in
                                                                                 own right.
conjunction with an industry
activity on site and are trade­related
only. Built form Table 6.5.2.3
Criteria for assessment. (part)
Performance outcomes All activities
Built form Height

PO8                                      AO8.1, AO8.2
                                                                                 Complies with AO
Performance outcomes Buildings           Acceptable Outcomes Buildings and
                                                                                 The building is existing, single storey, and
and other structures— (a) are low        structures are no more than 10
                                                                                 5.9 metres in overall height to the parapet
rise and have a visual bulk and          metres in building height.
                                                                                 as shown on sheet A301, well within the
architectural scale consistent with      AO8.2 The exposed portion of the
                                                                                 10 metre acceptable outcome. Visual bulk
structures on adjoining and nearby       external elevation of the building
                                                                                 and architectural scale are consistent with
land; (b) have a maximum building        cannot exceed 10 metres in building
                                                                                 the adjoining single storey service
height of two storeys; (c) do not        height and does not appear to
                                                                                 industry buildings. No increase in height
visually exceed two storeys when         exceed more than two storeys when
                                                                                 is proposed.
viewed externally from the               viewed externally from any
building; (d) do not visually            elevation.
dominate the street or surrounding
spaces; (e) preserve the amenity of
surrounding residential
development including privacy,
views and access to sunlight; and (f)
respond to the topography of the
site and minimise cut and fill where
on a sloping site; and (g) are well
arti
Log in to download the original file

Code Assessment - 12 Eenie Creek Rd (RESOLVED DRAFT).pdf · 527 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.