Code Assessment - 12 Eenie Creek Rd (RESOLVED DRAFT)
heights. Mechanical plant,
accepted development within the existing
equipment and storage
building without expansion of the use
area, so the adaptability of the premises is
preserved.
PO13 AO13.1, AO13.2
Complies with PO
Mechanical plant and equipment Mechanical plant, refuse and
This outcome expressly extends to air
(including air conditioning recycling area, vents and exhausts
conditioning equipment. A showroom of
equipment) and storage areas are are not visible from a street, public
this kind, with a fully glazed northern
designed and located to— (a) avoid space or adjoining residential use
frontage, will require air conditioning,
adverse visual impacts when and is acoustically screen from
and the concept drawings do not yet show
viewed from the street and adjoining sensitive land use.
where the plant is to be located. The
adjoining properties; and (b) AO13.2 Mechanical plant and
proposal is capable of satisfying both
visually integrate with the building equipment are: located more than 2
limbs of the performance outcome and
design. (a) (b) (c) (d) Streetscape metres from any property
the acceptable outcomes, as follows.
boundary; where located at ground
level, screened by fencing 1.5
The acoustic limb of AO13.1 is not
metres in height or dense
engaged. It applies to plant visible from,
vegetation of at least 1.5 metres in
or affecting, an adjoining residential use
width incorporating grouped trees
or sensitive land use. There is none. Both
and shrubs with a maximum
adjoining parcels, and all forty parcels
separation distance of 1 metre
within 150 metres, are in the Medium
measured from the centre of the
Impact Industry zone.
tree or shrub; visually integrated
into the line and plane of
As to the visual limbs, the existing
building presents to the street behind a
parapet at 5.9 metres, as shown on sheet
A301. Plant mounted at roof level behind
that parapet is not visible from the street
frontage or from adjoining properties, and
does not project beyond the height or
width of the building, satisfying AO13.2(c)
and (d). Where any plant is instead
located at ground level, it can be sited to
the rear of the building away from the
frontage and screened in accordance with
AO13.2(b).
The applicant offers, as a condition of any
approval, that all mechanical plant and
equipment including air conditioning be
located and screened in accordance with
AO13.2, and that its location be shown on
plans submitted for approval. Storage is
provided internally within the building as
shown on sheet A202 and is not visible
from the street.
One matter is noted for detailed design:
AO13.2(a) requires plant to be located
more than 2 metres from any property
boundary. The building occupies much of
this 809 square metre site, so a roof-
mounted location behind the parapet is
likely to be the practical solution, and is
in any event the better outcome visually.
PO14 No acceptable outcome provided
Not applicable
Visual amenity and character
The site does not adjoin the major road
surrounding the major road
network. It fronts the Eenie Creek Service
network No acceptable outcome
Road, a local service road.
provided is protected and enhanced