      BUSHFIRE CONSTRUCTION REQUIREMENTS
32.   The dwelling is located on a property that is affected by a bushfire hazard overlay, and is therefore required to
      be provided with on-site water storage of at least 5,000 litres. This water may be stored within the domestic
      tanks, but the 5,000 litres must be reserved exclusively for fire fighting. The existing rainwater tank provided
      to the shed can also be used for this purpose.
33.   The allotment is located in an area that has been designated as a Bushfire Prone Area, by the local authority.
      An assessment against AS3959 has determined that a Bushfire Attack Level of 12.5 applies.
      The building must incorporate construction methods applicable to this BAL as detailed in AS3959. A
      certificate from the builder (or other suitable competent person) must be provided at the completion of the
      works certifying compliance with these requirements.
      The owner of the property must ensure that the assessment criteria used to determine the BAL are maintained
      throughout the life of the building. This includes maintaining the minimum separation distance and undertaking
      appropriate maintenance of any asset protection zone.

HEALTH & AMENITY
34. Building elements in wet areas within the building must be waterproof or water resistant in accordance with
    Table 3.8.1.1 and comply with AS3740-2010.
35. Doors to a fully enclosed sanitary compartment must open outwards, slide, or be readily removable from the
    outside of the compartment (generally by the use of lift-off hinges) unless there is at least 1.2 metres between
    the toilet pan and the hinge part of the doorway (refer to BCA Figure 3.8.3.3).
36. Where a bathroom or laundry is not provided with compliant natural ventilation, an exhaust fan must be
    provided. The exhaust fans must discharge to outside the building or to the roof space if it is adequately
    ventilated by roof vents or the like.
37. Waterproofing membranes for external above ground use must comply with AS4654 Parts 1 & 2.2012.

SAFE MOVEMENT & ACCESS
38. All stairs are to be constructed in accordance with NCC Part 3.9.1. Stairs are to have a maximum of 18 rises.
     Stepped quarter landings must not have more than three winders. Riser openings must not allow a 125 mm
     sphere to pass through between the treads. The minimum allowed tread dimension is 240 mm, the maximum
     riser dimension is 190 mm, and the slop relationship (2R&G) is to be between 550-770 mm. All dimensions
     within the stair flight must be constant throughout.
39. A balustrade is required to be provided along the side of any stair or floor if its level above the surface beneath
     is more than 1m. Any required balustrade must be constructed in accordance with NCC Part 3.9.2, so it has a
     minimum height of 1m and a maximum gap of 125mm.
40. If a glass balustrade is used, the supporting balustrade framework must comply with AS1170 and AS1288.
     Relevant test certificates or a Form 15 from a registered engineer must be provided to confirm the balustrade
     is compliant.
41. Stairs, ramps and landings must be provided with a suitable slip resistant surface as required by Part 3.9.1.4
     of the BCA. Where timber or tiles are used as the finished surface, a certificate of compliance is to be
     provided.
42. A window opening must be protected if the floor below the window in a bedroom is 2m above the surface
     beneath. Refer to NCC Part 3.9.2.6 for protection requirements.

ENERGY EFFICIENCY
43. Energy Efficiency measures must be installed as detailed in the approved energy efficiency report. The
    builder is required to provide a certificate for any items which are not readily visible to the Building Certifier
    during the final inspection.

SUSTAINABLE BUILDING REQUIREMENTS (QDC Part MP4.1)
44. The dwelling (including patios and garage) must have artificial lighting complying with BCA2010 Part 3.12.5.5
    or energy efficient lighting for a minimum of 80% of the total fixed internal lighting.




49 DONNELLYS ROAD, RIDGEWOOD
PERMIT NO 8971                                                                                                PAGE 4 OF 6

Used in these records

About this file

File size
8.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment E - Secondary Dwelling (Exisitng Dwelling Plans from BA).pdf · 8.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.