                                                     Parking and Access Report17734
                                                      11-19 Hilton Terrace, Tewantin
                                                              Tewantin Retail Pty Ltd
                                                                           May 2017




4.2    Compliance with Australian Standards AS2890.1

A detailed assessment of the car parking arrangements has been undertaken.
All parking spaces are a width of 2.6m, length of 5.4m with aisle width of
6.6m. The proposed parking spaces comply with AS2890.1 (Figure 2.2).

The proposed disabled parking spaces comply with the requirements of
AS2890.6:2009 Figure 2.3.

The proposed motorcycle parking space are 1.2m wide and 2.5m long
complying with the requirements of Clause 2.4.7 of AS2890.1.

Clause 3.3 of AS2890.1 includes requirements for gradients of access
driveways. The grade for the access driveway from the road frontage (kerb) to
the property boundary is a maximum of 1 in 20 (5%). The proposed access
meets the requirements for access driveways.

Clause 3.2 of AS2890.1 includes requirements for access driveway widths
with a recommended minimum width of 5.5m. The proposed driveway is
6.0m wide complying with current guidelines.

The collection of waste and garbage will be undertaken within the site directly
from the designated refuse collection area. Waste collection vehicles will
manoeuvre within the site, to ensure vehicles enter and exit in forward
direction. Please refer to Appendix C for swept path analysis.

The parallel on-street parking spaces have also been checked against the
requirements of AS2890.5 On-street parking facilities. The proposed 8 parallel
spaces on Hilton Terrace are 2.1m wide and 6.3m long, complying with the
requirements of Clause 2.2 of AS2890.5

The driveway on Earnest Street has been designed to meet the requirements of
standard drawing R-051 for commercial driveways (refer to Appendix C).

In summary the proposed car parking spaces and aisle widths comply with the
requirements of AS2890 and are considered adequate and suitable for the
intended use.




                                                                              Page 8
Log in to download the original file

Att 7 - Traffic Report.pdf · 4.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.