                 Including amendments to 8 June 2018




                                                                     Specific Outcomes                            Acceptable solutions (if accepted
The Noosa Plan



                                                                                                               development subject to requirements)
                                                                                                              Probable solutions (if code assessment)
                                                                                                                 landslide emanating from the site or from
                                                                                                                 other land; or
                                                                                                           b)    identifies methods of stabilising all
                                                                                                                 buildings, accessways and use areas;
                                                                                                           AND
                                                                                                           S7.3 If the geo-technical report identifies
                                                                                                           methods of stabilising buildings, accessways
                                                                                                           and use areas, those methods are
                                                                                                           implemented.
                                                       Water Supply Infrastructure
                                                       O8 Existing water supply infrastructure,            S8.1 Buildings and structures are setback a
                                                       including pipeline corridor, is protected from      minimum of 20m from a water supply pipeline
                                                       incompatible development to ensure the safety       as shown on Overlay Map OM3.5.
                                                       and reliability of water supply network.
                                                       Gas Pipeline
                                                       O9 Adequate separation is provided between          S9.1 No new buildings for the purpose of
                                                       the new building works and the gas pipeline         Residential Uses (except for a Detached
                                                       shown on Overlay Maps OM3.5 or OM5.5;               house or class 10 building), Education uses,
                                                                                                           Wellbeing uses or Retail business uses are
                                                                                                           within 200m of the gas pipeline shown on
                                                                                                           Overlay Maps OM3.5 or OM5.5;
                                                       AND                                                 AND
                                                                                                           S9.2 Any building works for the purpose of
                                                                                                           storage of flammable, explosive or other
                                                                                                           hazardous materials are not within 200m of the
                                                                                                           gas pipeline shown on Overlay Maps OM3.5 or
                                                                                                           OM5.5.

                                                       O10 Building works are constructed and              S10.1 No solution provided (no requirement for
                                                       operated to avoid damaging or adversely             accepted development development).
                                                       affecting the operation of the pipeline and the
                                                       supply of gas.
                                                       14.95     Built form
                                                       Height
                                                       O11 Buildings and other structures–                 S11.1 The maximum building height in storeys
                                                       a)   are low rise and present a building height     and metres is—
                                                            consistent with structures on adjoining and    a)   if in the Visitor Mixed Use Zone – 12m
                                                            surrounding land;                                   (but not exceeding 3 storeys);
                                                       b)   have a maximum building height of–             b)   if in the Noosa Heads Locality, Attached
                                                             i)    for Visitor Mixed Use Zone - 3               Housing Zone –
                                                                   storeys;                                    a) Lot 4 on SP 100064 in Serenity Close
                                                             ii)   if in the Noosa Heads Locality,                    Noosa Heads - 15m (but not
                                                                   Attached Housing Zone—                             exceeding 4 storeys); or
                                                                   Lot 4 on SP 100064 in Serenity             b) otherwise - 12m (but not exceeding 3
                                                                        Close Noosa Heads - 4 storeys;                storeys);
                                                                   Otherwise - 3 storeys;                 c)   if in the Shire Business Centre Zone –
                                                             iii)  if in the Shire Business Centre             i. Precinct E1 or E2 - 12m (but not
                                                                   Zone—                                              exceeding 3 storeys);
                                                                   Precinct E1 or E2 - 3 storeys;             ii. Precinct REC/MU - 8m (but not
                                                                   Precinct REC/MU - 1 storey;                       exceeding 1 storey);
                                                             iv)   if in the Noosaville Locality and the   d)   if in the Noosaville Locality and the
                                                                   Attached Housing Zone - 2 or 3               Attached Housing Zone and with frontage
                                                                   storeys depending on the location            to the following streets – Russell St,
                                                                   of the site;                                 William St and Howard St, or Weyba Rd,


                                                                                                        14-102
                                                                                                 Building Works Code
Log in to download the original file

20181085-ASC7 - Part 14 Assessement Criteria (Codes) (1).pdf · 3.2 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.